The BurnerPRO™ provides the proper burner sequencing, ignition and continuous flame monitoring for commercial heating and process equipment firing oil and gas fuels.
BurnerPRO BP110UV-S1, S2,, S3 and BP230UV-S1, S2, S3 controls are plug and play compatible with select Siemens LFL control models. Use existing wiring base with no external wiring changes. The controls are also compatible with Satronic TMG controls with minor wiring changes. See the reverse side for compatibility listings.
The system is designed for use in non-permanent operations that requires burner recycle at least once every 24 hours. Seven SMART LEDs provide current operating status and lockout information in the event of a safety shutdown.
Item |
Part Number |
Description |
1 |
BP230UV-S1 |
BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 1 timings, with UV non-self check amplifier |
2 |
BP230UVF-S1 |
BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 1 timings, with UV non-self check amplifier, IP44 (Recommended for new installations - Contact Factory) |
3 |
BP230UV-S2 |
BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 2 timings, with UV non-self check amplifier |
4 |
BP230UVF-S2 |
BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 2 timings, with UV non-self check amplifier, IP44 (Recommended for new installations - Contact Factory) |
5 |
BP230UV-S3 |
BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 3 timings, with UV non-self check amplifier |
6 |
BP230UVF-S3 |
BurnerPRO Single Burner Control, 230VAC 50/60Hz, Series 3 timings, with UV non-self check amplifier, IP44 (Recommended for new installations - Contact Factory) |
7 |
BP110UV-S1 |
BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 1 timings, with UV non-self check amplifier |
8 |
BP110UVF-S1 |
BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 1 timings, with UV non-self check amplifier, IP44 (Recommended for new installations - Contact Factory) |
9 |
BP110UV-S2 |
BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 2 timings, with UV non-self check amplifier |
10 |
BP110UVF-S2 |
BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 2 timings, with UV non-self check amplifier, IP44 (Recommended for new installations - Contact Factory) |
11 |
BP110UV-S3 |
BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 3 timings, with UV non-self check amplifier |
12 |
BP110UVF-S3 |
BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 3 timings, with UV non-self check amplifier, IP44 (Recommended for new installations - Contact Factory) |
13 |
BP110UV-S6 |
BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 6 timings, with UV non-self check amplifier |
14 |
BP110UVF-S6 |
BurnerPRO Single Burner Control, 110VAC 50/60Hz, Series 6 timings, with UV non-self check amplifier, IP44 (Recommended for new installations - Contact Factory) |
"F" in the part number field represents Fireye version and it's recommended for new installations
BurnerPRO Wiring Base |
|
60-2981-1 |
Standard base with terminal block and knockouts, 4.2”L x 4.2”W x 1.22”H |
60-2944-1 (for “F” series only) |
Special base with terminal block and knockouts, 4.2”L x 4.2”W x 1.22”H |
61-7429-1 |
Grounding wire/leash, 10” length |